Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 651
Filter
1.
Braz. j. oral sci ; 21: e226999, jan.-dez. 2022. ilus
Article in English | LILACS, BBO | ID: biblio-1392965

ABSTRACT

Background: Tooth extraction socket in the aesthetic area is a major indication for immediate implant placement greatly improving patient satisfaction and preserving the alveolar ridge. However, the effect of non-axial force on the peri-implant bone with subsequent early implant failure remains unclear. Objective:Evaluate the prognosis of tilted implants immediately placed and restored with angled abutments in comparison to straight implants restored with straight abutments in the esthetic area (anterior or premolars) using computer-aided surgical guides. Material and methods: Badly decayed non-restorable teeth in the aesthetic zone (anterior or premolars) were extracted atraumatically. Immediately after guided implant insertion, the abutments were adjusted and placed according to the allocation group (0, 15, or 25-degree angle) then a temporary crown was performed out of occlusion in centric and eccentric relation. Early implant failure was assessed at three and six months. Results:There was no statistically significant difference between the two groups (P=0.305). Straight and angled abutment groups showed 6 (14.3%) and 8 (20%) failed cases, respectively. The post-hoc subgroup analysis showed no statistically significant difference between angle 15 and angle 25 degree groups where (P=0.686) or between Anterior and Premolar groups (P=0.853). Conclusion: There was no statistically significant difference in the failure rate when comparing angled to straight immediately placed & restored implants. This applies to both anterior and premolar implants


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Prognosis , Tooth Extraction , Weight-Bearing , Dental Restoration Failure , Dental Implantation , Immediate Dental Implant Loading
2.
Braz. j. oral sci ; 21: e226036, jan.-dez. 2022. ilus
Article in English | LILACS, BBO | ID: biblio-1393321

ABSTRACT

Dental implants could give back function, esthetics and quality of life to patients. The correct choice of the implant, especially in borderline cases, is essential for a satisfactory result. Aim: Thus, the objective of this study was to evaluate the mechanical behavior of Morse taper implants with two different prosthetic interfaces. Methods: Twenty self-locking Morse taper implants, 2.9 mm in diameter (FAC), and 20 Morse taper implants, 3.5 mm in diameter (CM) were divided into two groups (n=10), and submitted to strength to failure test, optical microscopic evaluation of fracture, metallographic analysis of the alloy, finite element analysis (FEA) and strain gauge test. A Student's t test (α = 0.05) was made for a statistical analysis. Results: For the strength to failure test, a statistically difference was observed (p <0.001) between FAC (225.0 ± 19.8 N) and CM (397.3 ± 12.5 N). The optical microscopic evaluation demonstrated a fracture pattern that corroborated with FEA ́s results. The metallographic analysis determined that the implants of the FAC group have titanium-aluminum-vanadium alloy in their composition. In the strain gauge test, there was no statistical difference (p = 0.833) between CM (1064.8 ± 575.04 µS) and FAC (1002.2 ± 657.6 µS) groups. Conclusion: Based on the results obtained in this study, ultra-narrow implants (FAC) should ideally be restricted to areas with low masticatory effort


Subject(s)
Tensile Strength , Dental Implantation , Flexural Strength
3.
Natal; s.n; 25 nov. 2022. 81 p. tab, ilus.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1532247

ABSTRACT

A estética e estabilidade dos tecidos moles e ósseo ao redor do implante é um componente crítico para o sucesso do implante em longo prazo e pode ser influenciado por fatores como os tipos de conexões protéticas. OBJETIVO: Comparar o comportamento do tecido peri-implantar em reabilitação com coroas implantossuportadas cimentadas na região estética usando um pilar protético pré-fabricado em titânio (GT) e um pilar protético personalizado em zircônia (GZ). METODOLOGIA: Neste estudo longitudinal do tipo ensaio clínico controlado, cego e não randomizado, 30 coroas cimentadas sobre implantes dentários unitários em região estética anterior foram alocados sequencialmente: 15 reabilitados sobre um sistema de implante com pilar protético pré-fabricado em titânio (GT) e 15 sobre um sistema de implantes com pilar protético personalizado em zircônia (GZ). O comportamento do tecido peri-implantar foi avaliado em T0 (início do condicionamento tecidual), T1 (fim do condicionamento tecidual), T2 (7 dias após cimentação final), T3 (6 meses após cimentação final). Índice de Placa Visível (IPV), Índice de Sangramento Gengival (ISG), Sangramento a sondagem (SS), Profundidade de Sondagem (PS), Relação Altura/Largura da papila interdental (AP/LP), Faixa de Mucosa Ceratinizada (MC), Espessura gengival (EG), Fenótipo periodontal (FP), Recessão Gengival (RG), distância radiográfica da crista óssea para o ponto de contato e Pink Esthetic Score (PES) foram avaliados. A análise dos dados foi realizada utilizando os seguintes testes estatísticos: Friedman, Mann-Whitney e Qui- quadrado/Exato de Fisher, com nível de significância de 5%. RESULTADOS: Não houve diferenças estatísticas significativas entre os grupos para nenhum dos parâmetros clínicos periodontais nos tempos avaliados (p>0,05). Entretanto, a análise intragrupo mostrou uma redução estatística no IPV e ISG entre T1 e T2 apenas para o GZ (p<0,05). Houve diminuição significativa entre os tempos T0 e T3 para o parâmetro de EG (1,67 mm - 1,47 mm no GT; 1,70 mm -1,47mm no GZ) e aumento da razão AP/LP (0,56 ­ 0,80 no GT; 0,70-0,83 no GZ) em ambos os grupos (p<;0.001). O PES também aumentou significativamente para ambos os grupos (9 ­ 12 no GT; 7 ­ 12 no GZ) de T0 para T1, mantendo-se elevado nos demais tempos analisados. CONLUSÃO: Os resultados mostraram que os pilares protéticos utilizados não impactaram em diferenças nas variáveis clínicas e estética relacionadas ao comportamento dos tecidos periimplantares ao longo do tempo. Sendo assim, a decisão pela seleção dos componentes para a reabilitação em região estética poderia se basear em aspectos como o custo, fluxo e tempo de trabalho (AU).


The esthetics and stability of the soft tissue and bone around the implant is a critical component to the long-term success of the implant and can be influenced by factors such as the type of prosthetic connections. OBJECTIVE: To compare the behavior of the periimplant tissue of single implant-supported crowns in the anterior aesthetic area using prefabricated titanium prosthetic abutments (GT) and customized zirconia prosthetic abutments (GZ). METHODOLOGY: In this controlled, blinded, non- randomized clinical trial, 30 single cemented crown over anterior implants were sequentially allocated: 15 implants rehabilitated on implant system with a prefabricated titanium prosthetic abutment (GT) and 15 on implant system with customized zirconia prosthetic abutment (GZ). The behavior of the peri- implant tissue was evaluated at T0 (beginning of tissue conditioning), T1 (end of tissue conditioning), T2 (7 days after final cementation), T3 (6 months after final cementation). Visible Plaque Index (VPI), Gingival Bleeding Index (GBI), Bleeding on Probing (BoP), Probing Depth (PD), Interdental Papilla Height/Width Ratio (PH/PW), Keratinized Mucosa Width (KM), Gingival Thickness (PT), Periodontal Phenotype (PF), Gingival Recession (GR), radiographic distance from the bone crest to the contact point and Pink Esthetic Score (PES) were registered. The results were analyzed with the following statistical tests: Friedman, Mann-Whitney and Chi- square/Fisher; Exact test with a significance level of 5%. RESULTS: No statistically significant differences were observed between groups for any of the clinical parameters in any, (p>0.05). However, intragroup analysis showed a statistical reduction in VPI between T1 and T2 only for GZ (p< 0.05). There was a significant decrease between T0 and T3 for GT (1.67 mm - 1.47 mm in GT, and 1.70 mm -1.47 mm in GZ) and increase in the ratio PH/PW (0.56 - 0.80 in GT and 0.70- 0.83 in GZ) in both groups (p<0.0001). PES also increased significantly for both groups (9 ­ 12 in GT and 7 ­ 12 in GZ) from T0 to T1 and remained high in the other periods. CONCLUSION: The results showed that the prosthetic abutments used did not impact differences in clinical and aesthetic variables related to the behavior of peri-implant tissues during the study. Therefore, the decision to select components an aesthetic area should be based on aspects such as cost, workflow and timing (AU).


Subject(s)
Tissue Conditioning, Dental , Dental Prosthesis, Implant-Supported , Esthetics, Dental , Chi-Square Distribution , Longitudinal Studies , Statistics, Nonparametric , Crowns , Dental Implantation , Mouth Rehabilitation
4.
Natal; s.n; 9 nov 2022. 158 p. tab, ilus, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1532385

ABSTRACT

Este estudo objetivou identificar os fatores que influenciam na decisão de substituir uma prótese total convencional mandibular pelo tratamento com implantes dentários, assim como avaliar a satisfação, qualidade de vida e performance mastigatória (PM) após reabilitação com sobredentaduras com implante único (SIU) em pacientes adaptados e não-adaptados a prótese total convencional (PT) mandibular. Inicialmente, foi realizado um estudo transversal com 117 usuários de PTs bimaxilares, avaliados quanto aos desfechos relacionados à prótese (número de PTs mandibulares usadas previamente, tempo de uso e profissional que confeccionou a prótese atual, e quanto ao uso regular ou não da prótese mandibular) e aspectos centrados no paciente (período de edentulismo mandibular, altura óssea mandibular e interesse do paciente em se submeter a terapia com implantes). Do total da amostra, 78 pacientes manifestaram interesse na terapia implantossuportada, e desses apenas 22 foram selecionados e reabilitados com novas PTs bimaxilares. Após critérios de elegibilidade, foram alocados após pareamento em 2 grupos: adaptados à prótese mandibular (Grupo PTA - "adaptados à PT mandibular", n:10) e não adaptados (Grupo PTN - "não adaptados à PT mandibular", n:12). Em cada paciente, foi instalado um único implante na linha média e após o período de osseointegração as próteses mandibulares foram convertidas em sobredentaduras. O desempenho mastigatório foi avaliado pelo método das tamises, a altura óssea mandibular por medição em radiografia panorâmica, satisfação por escala quantitativa com questionário validado e o impacto da saúde oral na qualidade de vida pelo questionário OHIP-Edent-19. O teste Qui-quadrado foi utilizado para análise dos dados e as razões de prevalência ajustadas por meio da regressão multivariada de Poisson no primeiro estudo; para o segundo, a análise estatística em cada grupo e entre grupos foi baseada nos testes não-paramétricos de Wilcoxon e Mann-Whitney. O intervalo de confiança para os testes foi de 95%. A amostra foi predominantemente do sexo feminino, com 66,7% (n=78) dos participantes interessados em PT mandibular implantossuportada e com idade média de 65,68±6,38 anos. A PM não influenciou a escolha pela reabilitação com implantes. A preferência pela PT implantossuportada mandibular foi associada significativamente com maior experiência prévia com PT mandibular (p=0,021) e à insatisfação quanto à retenção (p=0,005). Após a intervenção com implante, todos os pacientes não adaptados passaram a condição de adaptados. Não houve diferença entre PTA e PTN para OHIP-Edent (p=0,276) e PM (p=0,222), a satisfação foi significativa apenas para o critério "conforto em arco inferior" (p=0,043). Para comparações pré e pós-tratamento com sobredentadura, a mediana do OHIP-Edent total diminuiu significativamente em ambos os grupos. Na comparação intragrupo, essa redução foi significativa em PTA apenas para a "limitação funcional" (p=0,026), e em PTN em quase todos os domínios, exceto "disfunção social" e "incapacidade" (p>0,05). Houve aumento estatisticamente significativo para a satisfação geral de 75,41 para 90,25 (p=0,012) em PTN e de 76,10 para 90,50 (p=0,007) em PTA. Os parâmetros "mastigação", "adaptação", "retenção" e "conforto" em arco inferior foram diferentes com significância em ambos os grupos, e "gustação", "fonação" e "dor" em arco inferior foram significativos apenas para o grupo não adaptado (p<0,05). Houve diferença significativa para PM em PTN (p=0,002) e PTA (p=0,047) ao se comparar tipo de reabilitação. Não houve correlação entre PM e OHIP antes e após a reabilitação (p>0,05). Pode-se concluir que a experiência prévia com PT mandibulares convencionais e a insatisfação com a retenção dessas, influenciam o interesse pela reabilitação com sobredentadura implantossuportada mandibular, assim como, a reabilitação com sobredentadura sobre implante único apresenta-se como alternativa aos pacientes não adaptados a PT convencional mandibular, auxiliando na aceitação do uso da prótese mandibular, assim como, comprovando efeito positivo na satisfação, qualidade de vida e performance mastigatória (AU).


This study aimed to identify the factors that influence the decision to replace a conventional mandibular complete denture by treatment with dental implants, as well as to evaluate satisfaction, quality of life and masticatory performance (MP) after rehabilitation with overdentures with a single implant in patients adapted and not adapted to conventional mandibular complete denture (CD). Initially, a cross-sectional study was carried out with 117 users of bimaxillaries CDs, who were evaluated for outcomes related to the denture (number of previous mandibular CDs, time of use and professional who made the current denture, and regarding regular use of the mandibular denture) and aspects centered patients (period of mandibular edentulism, mandibular bone height and the patient's willingness to undergo implant therapy). From the total sample, 78 patients expressed interest in implant-supported therapy, and of these, only 22 were selected and rehabilitated with new bimaxillary CDs. After eligibility criteria, they were allocated after pairing into 2 groups: adapted to mandibular prosthesis (PTA Group - "adapted to mandibular CD", n:10) and non-adapted (PTN Group - " not adapted to mandibular CD", n:12). In each patient, a single implant was installed in the midline and after the osseointegration period, the mandibular prostheses were converted into overdentures. Masticatory performance was evaluated by the sieve method, mandibular bone height by paranoid radiographic measurement, satisfaction by quantitative scale with a validated questionnaire and the impact of oral health on quality of life by the OHIP-Edent-19 questionnaire. The chi-square test was used for data analysis and the prevalence ratios adjusted by means of multivariate Poisson regression in the first study; on the second, the statistical analysis in each group and between groups was based on the non-parametric-Wilcoxon and Mann-Whitney tests. The confidence interval for the tests was 95%. The sample was composed predominantly by women, with 66.7% (n=78) of the participants interested in implantsupported mandibular CD, with mean age 65.68±6.38 years. MP was not influenced by the choice by dental implants rehabilitation. Preference for mandibular implant-supported CD was significantly associated with longer previous experience in mandibular CD (p=0.021) and with dissatisfaction regarding retention (p=0.005). After the implant intervention, all non-adapted patients became adapted. There was no difference between PTA and PTN for OHIP-Edent (p=0.276) and MP (p=0.222), satisfaction was significant only for the criteria "comfort in the lower arch" (p=0.043). For pre- and post-treatment comparisons with overdentures, the median total OHIP-Edent decreased significantly in both groups. In the intragroup comparison, this reduction was significant in PTA only for "functional limitation" (p=0.026), and in PTN in almost all domains, except "social dysfunction" and "disability" (p>0.05). There was a statistically significant increase in overall satisfaction from 75.41 to 90.25 (p=0.012) in PTN and from 76.10 to 90.50 (p=0.007) in PTA. The parameters "chewing", "adaptation", "retention" and "comfort" in the lower arch were significantly different in both groups, and "gustation", "phonation" and "pain" in the lower arch were significant only for the group not adapted (p<0.05). There was a significant difference for MP in PTN (p=0.002) and PTA (p=0.047) when comparing the type of rehabilitation. There was no correlation between MP and OHIP before and after rehabilitation (p>0.05). It can be concluded that the previous experience with conventional mandibular CD and the dissatisfaction with the retention of these, influence the rehabilitation with mandibular implant-supported overdenture, as well as the rehabilitation with overdenture on single implant presents itself as an alternative for patients not adapted to mandibular conventional CD, helping to accept the use of mandibular prosthesis, as well as proving a positive effect on satisfaction, quality of life and masticatory performance (AU).


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Quality of Life , Denture, Complete , Mastication , Mouth Rehabilitation , Cross-Sectional Studies/methods , Patient Satisfaction , Statistics, Nonparametric , Mandibular Prosthesis Implantation , Dental Implantation , Immediate Dental Implant Loading
5.
Rev. cuba. estomatol ; 59(2): e3544, abr.-jun. 2022. graf
Article in Spanish | LILACS, CUMED | ID: biblio-1408393

ABSTRACT

Introducción: La elevación de seno maxilar con implante dental simultáneo, sin el uso de substitutos óseos, ha retomado la teoría del potencial de neoformación ósea, que el coágulo de sangre alojado bajo la membrana de Schneider por sí solo presenta. Excluyendo así la necesidad de materiales exógenos. Objetivo: Exponer la efectividad de la elevación de seno maxilar con implante dental simultáneo, sin el uso de injerto, mediante la evaluación de la cantidad de ganancia ósea vertical. Presentación de casos: Caso 1: Paciente de 62 años, género femenino, que fue sometida a una elevación de seno maxilar sin injerto e implante dental simultáneo, con técnica de ventana lateral debido a altura ósea reducida de 5,24 mm. Luego del período de seguimiento tomográfico de 12 meses, después de la carga protésica, se logró una altura ósea vertical de 10,2 mm, lo que dio como resultado una ganancia ósea vertical de 4,96 mm. Caso 2: Paciente de 48 años, género femenino, que fue sometida a una elevación de seno maxilar sin injerto e implante dental simultáneo, con técnica transalveolar, mediante el uso de piezoeléctrico debido a una altura ósea reducida de 8,33 mm. Luego del período de seguimiento radiográfico de 4 meses, antes de la carga protésica, se logró una altura ósea vertical de 11,55 mm, lo que dio como resultado una ganancia ósea vertical de 3,19 mm. Conclusiones: Con base en estos 2 informes de casos, la elevación de seno maxilar e implante dental simultáneo sin injerto se asocian con la reducción de la morbilidad quirúrgica, menor probabilidad de procesos infecciosos y menor costo de la cirugía. Por lo tanto, puede considerarse una alternativa quirúrgica para la colocación de implantes en el maxilar posterior superior debido a deficiencias óseas verticales, independientemente de la técnica (lateral o transalveolar(AU)


Introduction: Maxillary sinus lift with simultaneous dental implantation without using bone substitutes, reapproaches the theory about the bone neoformation potential of the blood clot housed under the Schneider membrane, all by itself, thus excluding the need to use exogenous materials. Objective: Discuss the effectiveness of graftless maxillary sinus lift with simultaneous dental implant placement through an evaluation of the amount of vertical bone gain. Case presentation: Case 1: Female 62-year-old patient undergoing graftless maxillary sinus lift with simultaneous dental implantation by lateral window technique due to a reduced bone height of 5.24 mm. After a 12-month tomographic follow-up period subsequent to prosthetic loading, a 10.2 mm vertical bone height was achieved, resulting in 4.96 mm vertical bone gain. Case 2: Female 48-year-old patient undergoing graftless maxillary sinus lift with simultaneous dental implantation by transalveolar technique using a piezoelectric generator due to a reduced bone height of 8.33 mm. After a 4-month radiographic follow-up period, before prosthetic loading, an 11.55 mm vertical bone height was achieved, resulting in 3.19 mm vertical bone gain. Conclusions: According to these two case reports, graftless maxillary sinus lifting with simultaneous dental implantation is associated to reduced surgical morbidity, a lesser probability of infectious processes and lower surgical costs. It may therefore be considered to be a surgical alternative for implant placement in the posterior maxilla due to vertical bone deficiencies, regardless of the technique used (lateral or transalveolar(AU)


Subject(s)
Humans , Female , Middle Aged , Dental Implantation/methods , Sinus Floor Augmentation/methods , Aftercare , Costs and Cost Analysis
6.
Article in English | LILACS | ID: biblio-1369047

ABSTRACT

ABSTRACT: Among the treatment options for Obstructive Sleep Apnea (OSA) we have surgery to correct dentofacial deformities. OSA patients are routinely and predictably submitted to surgical treatment for dentofacial deformities. Frequently, orthognathic surgery and osseointegrated implants may be necessary to enable fixed rehabilitation. Patients submitted to orthognathic surgery have a transient decrease in blood supply after maxillary and mandibular osteotomy procedures, which can impair the results in these cases. This case report aimed to present and discuss the conflicting situation of an OSA patient in need of orthognathic surgery and dental implants. The treatment consisted of: (1) extraction of all teeth; (2) complete rehabilitation of the upper and lower jaw with dental implants and prosthesis without compensation; (3) bimaxillary orthognathic surgery to re-establish the maxillomandibular relationship and increase the upper airway volume. This rehabilitation sequence was a safe alternative for a case of Class II OSA, and rapidly achieved a final restoration with enhanced esthetics, functionality, biomechanics, maintenance of oral hygiene, and patient satisfaction. (AU)


RESUMO: Entre as opções de tratamento da Apneia Obstrutiva do Sono (AOS) temos a cirurgia para correção das deformidades dentofaciais. Freqüentemente, a combinação de cirurgia ortognática e implantes osseointegráveis pode ser necessária para permitir a reabilitação dental. Pacientes submetidos à cirurgia ortognática apresentam diminuição transitória do suprimento sanguíneo após procedimentos de osteotomia maxilar e mandibular, o que pode prejudicar os resultados nestes casos. Este relato de caso teve como objetivo apresentar e discutir a situação de um paciente com AOS que necessita de cirurgia ortognática e implantes dentários. O tratamento consistiu em: (1) extração de todos os dentes; (2) reabilitação completa da mandíbula superior e inferior com implantes dentários e próteses sem compensação; (3) cirurgia ortognática bimaxilar para restabelecer a relação maxilomandibular e aumentar o volume das vias aéreas superiores. Essa sequência de reabilitação foi uma alternativa segura para um caso de AOS Classe II, e rapidamente alcançou uma reabilitação com estética, funcionalidade, biomecânica aprimorada, manutenção da higiene oral e satisfação do paciente. (AU)


Subject(s)
Humans , Female , Adult , Sleep Apnea, Obstructive/rehabilitation , Dental Implantation , Orthognathic Surgical Procedures/rehabilitation
7.
Rev. Bras. Cancerol. (Online) ; 68(4): e-102713, Out-Dez. 2022.
Article in English, Portuguese | SES-SP, LILACS | ID: biblio-1451878

ABSTRACT

Introdução: O uso dos implantes osseointegrados para reabilitação de pacientes com dificuldade de adaptação de próteses convencionais mostra-se mais frequente a cada dia. Um grande grupo candidato à reabilitação com essa modalidade são os pacientes tratados para as neoplasias de cabeça e pescoço (CP). A irradiação na região de CP pode ser limitante para a instalação de implantes, porém a literatura apresenta evidências de técnicas e planejamentos favoráveis ao procedimento nesse grupo de pacientes. As técnicas menos traumáticas para intervenções na cavidade oral devem ser avaliadas, e os guias cirúrgicos para colocação de implantes podem ser aliados nesses procedimentos. Relato do caso: Paciente do sexo feminino, 64 anos, tratada com cirurgia, quimioterapia e radioterapia em cavidade oral para um carcinoma espinocelular (CEC) em língua e, em um segundo momento, diagnosticada e tratada com cirurgia para CEC em região de rebordo alveolar maxilar esquerdo por meio de hemipalatecmia, necessitava de reabilitação com implantes osseointegrados na região onde havia sido tratada com radiação primariamente. Realizou-se a cirurgia de colocação dos implantes com a tecnologia guiada para acarretar o mínimo trauma às estruturas bucais. Conclusão: O procedimento cirúrgico foi executado com sucesso. Atualmente, aguarda-se o período de osseointegração para a posterior reabilitação protética


Introduction: The use of osseointegrated implants for the rehabilitation of patients with difficulty fitting conventional prostheses is becoming more frequent every day. A great eligible group for rehabilitation with this modality are patients treated for head and neck cancer (HNC). Irradiation in the region of HN may be limiting for implants, but there are evidences in the literature of techniques and planning favorable to the procedure in this group of patients. Less traumatic techniques for interventions in the oral cavity should be evaluated, and surgical guides for implant placement may be allies in these procedures. Case report: A 64-year-old female patient, treated with surgery, chemotherapy and radiotherapy in the oral cavity for a squamous cell carcinoma (SCC) in the tongue and, in a second moment, diagnosed and treated with surgery for SCC in the region of the left maxillary alveolar ridge by means of hemipalatectomy, needed rehabilitation with osseointegrated implants in the region where she had been primarily treated with radiation. The implant placement surgery was then planned and performed using guided technology so that minimal trauma to the oral structures could occur. Conclusion: The surgical procedure was successfully performed, and the patient is now waiting for the osseointegration period for posterior prosthetic rehabilitation


Introducción: El uso de implantes osteointegrados para la rehabilitación de pacientes con dificultades de adaptación de las prótesis convencionales es cada vez más frecuente. Un gran grupo de candidatos a la rehabilitación con esta modalidad son los pacientes tratados por neoplasias de cabeza y cuello (CC). La irradiación en la región del CC puede ser limitante para la instalación del implante, sin embargo, la literatura presenta evidencias de técnicas y planificación favorables al procedimiento en este grupo de pacientes. Deben evaluarse técnicas menos traumáticas para las intervenciones en la cavidad oral, y las guías quirúrgicas para la colocación de implantes pueden ser un aliado en estos procedimientos. Caso clínico: Paciente de 64 años, mujer, tratada con cirugía, quimioterapia y radioterapia en la cavidad oral por un carcinoma de células escamosas (CCE) en la lengua y en un segundo momento diagnosticada y tratada con cirugía por CCE en la región de la cresta alveolar maxilar izquierda mediante hemipalatectomía, necesitó rehabilitación con implantes osteointegrados en la región donde había sido tratada principalmente con radiación. La cirugía de colocación de implantes se realizó con tecnología guiada para causar el menor traumatismo en las estructuras orales. Conclusión: La intervención quirúrgica se llevó a cabo con éxito. Actualmente se espera el periodo de osteointegración para la posterior rehabilitación protésica


Subject(s)
Humans , Female , Middle Aged , Carcinoma, Squamous Cell/radiotherapy , Osseointegration , Dental Implantation , Head and Neck Neoplasms , Mouth Rehabilitation
8.
Braz. dent. sci ; 25(4): 1-7, 2022. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1396066

ABSTRACT

Objective: The aim of this study was to evaluate the transcrestal sinus lift using Osseodensification technique with simultaneous implant placement. Material and Methods: In this case series 7 patients who needed implant placement in the atrophic posterior maxilla were enrolled. In all the cases the residual bone height between the sinus floor and the alveolar crest was 4-6 mm. Transcrestal sinus lift was performed using Osseodensification with simultaneous implant placement. Cone-beam computed tomography (CBCT) were obtained immediately postoperative and 6 months after operation. Implant stability using Osstell® were assessed at the time of implant placement and implant exposure (6 months). Results: The results showed that the mean bone height gain was 5.33±0.83mm at 6 months postoperatively. Mean bone density value was 818.43±109.63 HU. Mean ISQ value was 80.00±3.11 at 6 months postoperatively. The duration of surgical procedure (minutes) ranged between 25-38 minutes with an average of 30.86±4.10 minutes. Conclusion: The crestal maxillary sinus floor elevation using Osseodensification technique with simultaneous implant placement provide superior results regarding bone density and implant stability and less duration of surgical procedure. (AU)


Objetivo: O objetivo deste estudo foi avaliar a elevação de seio maxilar via crista do rebordo com a técnica de Osseodensificação com instalação simultânea de implante. Material e Métodos: Nesta série de casos, participaram 7 pacientes que necessitavam de implantes em região posterior de maxila atrófica. Em todos os casos a altura de remanescente ósseo entre o soalho do seio e a crista alveolar estava entre 4 a 6 mm. A elevação de seio maxilar via crista do rebordo foi realizada com osseodensificação com instalação simultânea de implante. As Tomografias Computadorizadas Cone Beam (TCCB) foram obtidas imediatamente após a cirurgia e 6 meses depois. A estabilidade dos implantes utilizando Osstell® foi avaliada no momento da instalação do implante e no momento da reabertura (6 meses). Resultados: Os resultados mostraram que a média de ganho de altura óssea foi de 5.33±0.83mm após 6 meses da cirurgia. A média da densidade óssea foi de 818.43±109.63 HU. A média de ISQ foi de 80.00±3.11 após 6 meses da cirurgia. A duração do procedimento cirúrgico (minutos) foi entre 25 a 38 minutos com uma média de 30.86±4.10 minutos. Conclusão: A elevação do soalho de seio maxilar via crista do rebordo com instalação simultânea de implante utilizando osseodensificador promove resultados superiores em relação à densidade óssea, estabilidade do implante e menor duração do tempo cirúrgico (AU)


Subject(s)
Humans , Male , Female , Adult , Osteotomy , Alveolar Bone Loss , Bone Substitutes , Dental Implantation , Cone-Beam Computed Tomography , Sinus Floor Augmentation
9.
Rev. odontol. UNESP (Online) ; 51: e20210024, 2022. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1377169

ABSTRACT

Introduction: Screw-retained restorations have a screw access hole (SAH) sealed with resin composite aiming at safe-guarding the aesthetic features of the ceramic veneer. The loss or wear of the resin composite applied in sealing the SAH is among the most common complications in implant prosthodontics, as the fracture of ceramic veneer. Objective: Evaluate the influence of sealant materials on the fracture resistance of resin composite applied in sealing screw access hole in screwed (SAH) implants. Material and method: The samples were produced from UCLA abutments in metallic NiCr alloy with subsequent application of ceramic. After asperisation and conditioning ceramic surface, was applied silane and dentin adhesive, before sealing the conduits with resin composites Z100 and P60. Nine groups (n=10) were evaluated: sealing with Z-100 (ZNC) and P-60 (PNC) without obturation of SAH; sealing with Z100 (ZCP) and P-60 (PCP) with absorbent cotton; Z100 (ZPT) and P60 (PPT) with polytetrafluoroethylene; Z100 (ZGP) and P60 (PGP) with gutta-percha and a cemented ceramic crown (ICS). After the fracture resistance test, the data were analyzed using two-way ANOVA and Tukey HSD tests (p<.05). Result: The fracture mode was evaluated by scanning electron microscope. Irrespective of the filling material, the highest mean values of fracture resistance were observed in the sealing with P60 (p=.002). When combined with resins composed of a sealing material, the results obtained were: ZGP: 805.5N/ PGP: 929.5N

Introdução: As próteses parafusadas possuem orifício de acesso ao parafuso (SAH), os quais são selados com resina composta. Sua perda ou desgaste está entre as complicações mais comuns em próteses sobre implantes, associadas a fratura da lâmina cerâmica. Objetivo: Assim, é importante avaliar a influência dos materiais de selamento na resistência à fratura de resina composta aplicada ao SAH no selamento de prótese sobre implantes parafusadas. Material e método: As amostras foram produzidas utilizando pilares UCLA em liga metálica de NiCr com posterior aplicação de cerâmica. Após asperização e condicionamento da superfície cerâmica, foram aplicados silano e adesivo dentinário, antes da selagem dos condutos com as resinas compostas Z100 e P60. Foram avaliados nove grupos (n = 10): selamento com Z-100 (ZNC) e P-60 (PNC) sem selamento do SAH; selamento com Z100 (ZCP) e P-60 (PCP) com algodão absorvente; Z100 (ZPT) e P60 (PPT) com politetrafluoroetileno; Z100 (ZGP) e P60 (PGP) com guta-percha e coroa de cerâmica cimentada (ICS). Após o teste de resistência à fratura, os dados foram analisados usando ANOVA de dois fatores e testes Tukey HSD (p<0,05). O tipo de fratura foi avaliado por microscópio eletrônico de varredura. Resultado Independentemente do material obturador, os maiores valores médios de resistência à fratura foram observados no selamento com P60 (p=0,002). Quando combinados com resinas compostas por um material de selamento, os resultados obtidos foram: ZGP: 805,5N/ PGP: 929,5N

Subject(s)
Microscopy, Electron, Scanning , Analysis of Variance , Composite Resins , Dental Prosthesis, Implant-Supported , Dental Implantation , Flexural Strength , Mouth Rehabilitation
10.
Braz. dent. sci ; 25(1): 1-8, 2022. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1352731

ABSTRACT

Objective: to evaluate the impact of three different scan strategies and implant angulation on impression accuracy of an intraoral scanner for full-arch multiple implant scan. Material and Method: A maxillary edentulous model with six implant analogs served as a reference model. The four anterior analogs were positioned parallel to each other, the distal right and the distal left was placed with an angulation of 15o and 20o, respectively. Thirty impression were performed using an intraoral scanner (CEREC Primescan). The master cast was digitalized with an industrial reference scanner (ATOS Core 80). All scans were converted to standard tessellation language (STL), superimposed on the reference scan with a 3d inspection software (GOM Inspect Professional 2019) and then analyzed. Results: All linear distances presented equivalence [p<0.01] to those found on the reference scan for all scan strategies. All scan strategies presented a tendency of negative means for linear distances except for d4 in strategy C. All angular distances did not present equivalence [p=0.05] to those found on the reference scan. Significant 3D deviations [p<0.05] were found between strategy B (0.02 ± 0.01) and C (0.05 ± 0.04) for d1. In all others linear and angular distances no statistically significant difference was found between strategies A, B and C. Conclusions: There was no statistically significant difference between strategies A, B and C except for d1 in strategy B and C; Implant angulation did not affect the accuracy of the CEREC Primescan IOS (AU)


Objetivo: avaliar o impacto de três diferentes estratégias de escaneamento e angulação do implante na acurácia da moldagem de um scanner intraoral na moldagem de múltiplos implantes em arco completo. Material e Métodos: Um modelo edêntulo de maxila contendo seis análogos de implante serviu como modelo de referência. Os quatro análogos anteriores foram posicionados paralelos entre si, o distal direito e o distal esquerdo foram posicionados com angulação de 15o e 20o, respectivamente. Trinta moldagens foram realizadas usando um scanner intraoral (CEREC Primescan). O modelo mestre foi digitalizado com um scanner de referência industrial (ATOS Core 80). Todas as escaneamentos foram convertidas para a linguagem de mosaico padrão (STL), sobrepostas ao escaneamento de referência com um software de inspeção 3D (GOM Inspect Professional 2019) e, em seguida, analisadas. Resultados: Todas as distâncias lineares apresentaram equivalência [p <0,01] àquelas encontradas na escaneamento de referência para todas as estratégias. Todas as estratégias de escaneamento apresentaram tendência de médias negativas para distâncias lineares, exceto para d4 na estratégia C. Todas as distâncias angulares não apresentaram equivalência [p = 0,05] às encontradas no escaneamento de referência. Desvios 3D significativos [p <0,05] foram encontrados entre a estratégia B (0,02 ± 0,01) e C (0,05 ± 0,04) para d1. Em todas as outras distâncias lineares e angulares, nenhuma diferença estatisticamente significativa foi encontrada entre as estratégias A, B e C. Conclusões: Não houve diferença estatisticamente significante entre as estratégias A, B e C, exceto para d1 na estratégia B e C; A angulação do implante não afetou a precisão do CEREC Primescan. (AU)


Subject(s)
Dental Implantation , Precision Medicine , Models, Anatomic
11.
Pesqui. bras. odontopediatria clín. integr ; 22: e210131, 2022. tab, graf
Article in English | LILACS, BBO | ID: biblio-1365225

ABSTRACT

Abstract Objective: To analyze and compare changes of quality of life parameter among dental patients rehabilitated by the implant-supported overdentures with different attachment systems. Material and Methods: Forty-eight patients were recruited as a study cohort. The implant placement procedure was based on the results obtained by CBCT scanning and individualized surgical templates manufactured for correct implant placement. Each individual received two k3Pro Implants (Sure Type with 4.0 or 4.5 mm in diameter) at the intraforaminal area due to standard protocol of implantation provided by the manufacturer under local anesthesia. All patients were distributed between two groups based on the fact of using either Locator- or ball-attachments. Rank correlation was measured using Spearman correlation coefficient, while linear correlation was evaluated by Pearson correlation coefficient. Results: No statistically meaningful differences were noted regarding patients' distribution among groups considering age (p>0.05) and gender (p>0.05). Provided patient-level analysis demonstrated that increase of conventional full denture service time was positively correlated with escalation of OHIP-EDENT scores. The most prominent inter-correspondences were noted specifically between longevity of denture service and elevation of scores within "Functional limitation" (r=0.61; p<0.05), "Physical pain" (r=0.51; p<0.05) and "Physical disability" (r=0.57; p<0.05) subdomains. No statistically argumented regressions were noted between increase tendency of OHIP-EDENT scores and gender (p>0.05) or age (p>0.05) parameters. Conclusion: Significant improvements of quality of life measured with OHIP-EDENT were noted for both types of attachments compared to the pre-treatment situation independently of additionally provided surface electromyography-based alignment.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Aged, 80 and over , Quality of Life , Dental Prosthesis, Implant-Supported/instrumentation , Electromyography/instrumentation , Masticatory Muscles , Ukraine , Surveys and Questionnaires , Regression Analysis , Cohort Studies , Statistics, Nonparametric , Occlusal Adjustment , Adaptation to Disasters , Dental Implantation , Denture, Complete , Denture, Overlay
12.
Natal; s.n; 13 dez. 2021. 115 p. tab, ilus, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1532964

ABSTRACT

A terapia cirúrgica tem sido apontada como a estratégia mais apropriada para o tratamento da peri-implantite. Uma dessas técnicas é a implantoplastia, cuja proposta é a modificação da superfície do implante através da remoção de roscas expostas, tornando-a menos aderente ao biofilme. O estudo objetivou avaliar o efeito da implantoplastia no tratamento da peri-implantite, através da comparação entre dois grupos de intervenção: um com e outro sem implantoplastia. Assim, trata-se de um ensaio clínico prospectivo, controlado, randomizado e cego. 13 participantes com 33 implantes foram alocados aleatoriamente em dois grupos: acesso cirúrgico + debridamento mecânico (grupo controle-I) e acesso cirúrgico + debridamento mecânico + implantoplastia (grupo teste- II). Os desfechos primários foram avaliados no baseline e aos 3 meses: Índice de Placa Visível -IPV, Índice de Sangramento Gengival -ISG, Profundidade de Sondagem -PS, Sangramento à Sondagem -SS e Faixa de Mucosa Ceratinizada -MC. Avaliou- se a qualidade de vida pelo Oral Health Impact Profile -OHIP14 e também os marcadores de estresse oxidativo pelas amostras salivares. Os resultados apontaram que 69,2% eram mulheres, com idade média de 60,6 anos. Dos 32 implantes, 16 receberam a terapia I e 16 a terapia II. De todas as reabilitações, 53,8% foram totais e 30,8% foram parciais, sendo as demais unitárias. O teste de Mann-Whitney apontou que os valores de IPV e do ISG no grupo II foram maiores do que no grupo I aos 3 meses, mas não foram significativos (p=0,193; p=0,419). O SS foi maior no grupo I (50%) do que no grupo II (41,6%) aos 3 meses, porém, sem significância (p=0,759). Aos 3 meses, todos os parâmetros - exceto SS no grupo II - diminuíram de valor, sendo significativos para o IPV no grupo I (p=0,038), ISG nos grupos I e II (p=0,011 e p=0,015) e PS no grupo II (p=0,041). O ANOVA Split-Plot não mostrou interação entre tempo e tratamento. O OHIP14 mostrou que no baseline houve predomínio da "Dor física", "Desconforto psicilógico" e "Incapacidade física", enquanto que aos 3 meses houve melhora dos itens avaliados. A análise salivar mostrou que houve uma redução dos níveis de marcadores de estresse oxidativo após o tratamento, sendo significativo para o superóxido dismutase (Z=-2,701; p=0,007). Conclusão: não há evidências suficientes de que a adição da implantoplastia melhore os parâmetros clínicos no tratamento cirúrgico da peri-implantite aos 3 meses, em relação ao debridamento mecânico realizado de forma isolada (AU).


Surgical therapy has been identified as the most appropriate strategy for the treatment of peri-implantitis. One of these techniques is implantoplasty, whose proposal is to modify the surface of the implant by removing exposed threads, making it less adherent to the biofilm. The study aimed to evaluate the effect of implantoplasty in the treatment of peri-implantitis, by comparing two intervention groups: one with and the other without implantoplasty. Thus, it is a prospective, controlled, randomized and blinded clinical trial. 13 participants with 33 implants were randomly allocated into two groups: surgical access + mechanical debridement (control-I group) and surgical access + mechanical debridement + implantoplasty (test-II group). The primary outcomes were assessed at baseline and at 3 months: Plaque Index -PI, Gingival Bleeding Index -GBI, Probing Depth -PD, Bleeding on Probing -BoP, and Keratinized Mucosal Band -MK. Quality of life was evaluated by the Oral Health Impact Profile -OHIP14 and oxidative stress markers by salivary samples. The results showed that 69.2% were women, with an average age of 60.6 years. Of the 32 implants, 16 received therapy I and 16 received therapy II. Of all rehabilitations, 53.8% were total and 30.8% were partial, with the rest being single. The Mann-Whitney test showed that the values of PI and GBI in group II were higher than in group I at 3 months, but they were not significant (p=0,193; p=0,419). The BoP was higher in I group (50%) than in II group (41.6%) at 3 months, however, without significance (p=0,759). At 3 months, all parameters - except BoP in II group - decreased in value, being significant for PI in I group (p=0,038), GBI in I and II groups (p=0,011 and p=0,015) and PD in II group (p=0,041). Split-Plot ANOVA showed no interaction between time and treatment. The OHIP14 showed that at baseline there was a predominance of "Physical pain", "Psychological discomfort" and "Physical disability", while at 3 months there was an improvement in the evaluated items. Salivary analysis showed that there was a reduction in the levels of oxidative stress markers after treatment, being significant for superoxide dismutase (Z=-2,701; p=0,007). Conclusion: there is insufficient evidence that the addition of implantoplasty improves clinical parameters in the surgical treatment of peri-implantitis at 3 months, in relation to mechanical debridement alone (AU).


Subject(s)
Humans , Male , Adolescent , Adult , Middle Aged , Aged , Quality of Life , Efficacy , Dental Implantation , Peri-Implantitis/therapy , Oral Hygiene , Double-Blind Method , Prospective Studies , Analysis of Variance , Statistics, Nonparametric , Peri-Implantitis/surgery
13.
Article in Portuguese | LILACS | ID: biblio-1353484

ABSTRACT

RESUMO: Introdução: A dissecção da artéria carótida (DAC) tem como uma das principais repercussões o Acidente Vascular Cerebral isquêmico (AVCi) em indivíduos jovens previamente saudáveis. É comum que nas DAC traumáticas, como em acidentes automobilísticos, o paciente seja submetido à investigação mais complexa com exames de imagem. Estes permitem um diagnóstico precoce e, portanto, um tratamento, reduzindo as chances de sequelas. Todavia, cau-sas não traumáticas com desfecho de DAC já foram relatadas, como as causas odontológicas. Objetivo: Contribuir para valorização diagnóstica da DAC não traumática e profilaxia de AVC subsequente. Métodos: Relatamos um caso de dissecção não aneurismática das artérias carótidas internas (ACI) pós-procedimento odontológico com desfecho de AVC bilateral em paciente de 52 anos. Resultados: Devido à forte associação de DAC a fatores traumáticos, em um primeiro contato com a paciente não foram levantadas suspeitas da ocorrência de DAC nem de AVC (ausência de déficit focal). Porém, tardiamente, foi identificada oclusão da ACI à esquerda e estenose na ACI direita, resultando em dois AVCs e incapacidade funcional severa na alta. Conclusão: O diagnóstico da DAC é um desafio, em especial por tratar-se de uma lesão de etiologia multifatorial. No entanto, seu reconhecimento precoce afetará diretamente o desfecho do paciente. Portanto, na presença de eventuais sintomas de alerta, faz-se necessário um meticuloso ques-tionamento sobre as últimas atividades do indivíduo. Este estudo alerta para a adoção de condutas profiláticas na ocorrência de fatores causais como hiperextensão cervical prolongada ou movimentos súbitos da cervical. (AU)


ABSTRACT: Introduction: Carotid artery dissection (CAD) has the ischemic stroke as one of the main repercussions in pre-viously healthy young individuals. It is common that in traumatic CAD, as in automobile accidents, the patient is subjected to a more complex investigation with imaging exams. These, allow an early diagnosis and, therefore, a treatment, reducing the chances of sequelae. However, non-traumatic causes with CAD outcomes have already been reported, such as dental causes. Objective: To contribute to the diagnostic valuation of non-traumatic CAD and subsequent stroke prophylaxis. Methods: We report a case of non-aneurysmatic dissection of the internal carotid arteries (ICA) after a dental procedure with evolution to bilateral stroke outcome in a 52-year-old patient. Results: Due to the strong association of CAD with traumatic factors, in a first contact with the patient there was no suspicion of CAD or stroke (absence of focal deficit). However, late, ICA occlusion on the left and stenosis on the right ICA were identified, resulting in two strokes and severe functional disability at discharge. Conclusion:The diagnosis of CAD is a challenge, especially since it is a multifactorial lesion. However, its early recognition will directly affect the patient's outcome. Therefore, in the presence of any warning symptoms, meticulous questioning about the individual's latest activities is necessary. This study alerts to the adoption of prophylactic conducts in the occurrence of causal factors such as prolonged cervical hyperextension or sudden movements of the cervical. (AU)


Subject(s)
Humans , Female , Middle Aged , Carotid Artery, Internal, Dissection , Stroke , Dental Implantation , Ischemic Stroke
14.
Medisan ; 25(4)2021. ilus
Article in Spanish | LILACS, CUMED | ID: biblio-1340215

ABSTRACT

Se presenta el caso clínico de un paciente que a los 7 años de edad fue remitido a la Clínica Estomatológica Provincial Docente Mártires del Moncada de Santiago de Cuba por presentar un quiste dentígero y displasia fibrosa monostótica. Desde entonces, y durante casi 10 años, el paciente ha sido atendido por un equipo multidisciplinario odontopediátrico, que ha seguido su evolución y ha aplicado diferentes protocolos diagnósticos y terapéuticos; estos últimos han incluido intervenciones quirúrgicas, rehabilitaciones protésicas, quimioterapia, entre otros. Por la complejidad del caso y la poca frecuencia con que aparecen asociadas ambas entidades clínicas en la infancia, se decidió comunicar este artículo al gremio odontológico nacional y extranjero.


The case report of a seven years old child who was referred to Mártires del Moncada Provincial Teaching Stomatological Clinic in Santiago de Cuba, who had a dentigerous cyst and monostotic fibrous displasia is presented. Since then, and almost during 10 years, the patient has been assisted by a multidisciplinary odontopediatric team, which has followed his clinical course and has applied different diagnostic and therapeutic protocols, including surgical procedures, prosthetic rehabilitations, chemotherapy, among others. Due to the case complexity and the frequency with which both clinical entities are associated in childhood, it was decided to publish this work for the national anf foreing odontological community.


Subject(s)
Dentigerous Cyst/diagnosis , Fibrous Dysplasia, Monostotic/diagnostic imaging , Mouth Rehabilitation , Dentigerous Cyst/surgery , Dentigerous Cyst/therapy , Dental Implantation
15.
Medisan ; 25(1)ene.-feb. 2021. ilus
Article in Spanish | LILACS, CUMED | ID: biblio-1154856

ABSTRACT

Los implantes dentales son una opción de restauración estética, funcional y armónica, cuya tasa de éxito es superior a 95 %. Se presenta el caso clínico de una paciente de 24 años de edad, atendida en la consulta de Ortodoncia de la Clínica Estomatológica Provincial Docente Mártires del Moncada de Santiago de Cuba, quien fue remitida desde el Servicio de Prótesis Estomatológica, con el fin de lograr el espacio adecuado para colocarle un implante, pues desde los 12 años de edad aproximadamente había perdido un diente a causa de caries. La restauración protésica mediante el implante dental proporcionó un excelente resultado.


Dental implants are an option of cosmetic, functional and harmonic repairs whose rate of success is higher than 95 %. The case report of a 24 years patient is presented. She was assisted in the Orthodontics Service of Mártires del Moncada Teaching Provincial Stomatological Clinic in Santiago de Cuba and was referred from the Stomatological Prosthesis Service, with the purpose of achieving the appropriate space to place an implant, because she had lost a tooth due to dental decay since she was approximately 12 years. The prosthetic repair by means of dental implant provided an excellent result.


Subject(s)
Osseointegration , Dental Implantation/methods , Orthodontics , Prostheses and Implants , Dentistry
16.
Archives of Orofacial Sciences ; : 67-72, 2021.
Article in English | WPRIM | ID: wpr-962459

ABSTRACT

ABSTRACT@#Currently dental implant treatment become popular. More clinicians are being presented with the opportunity to perform implant services in their own practice. The use of one-piece implant can be considered as treatment for the replacement of missing tooth in the areas of limited tooth-to-tooth spacing and would bring less trauma for the soft tissue. A 52-year-old female patient presented with difficulty in mastication due to the loss of teeth of 35 region with limitation mesio distal space. Radiology examination did not reveal any radiolucencies in 35 region. Radiograph revealed sufficient bone height from crestal to the floor of the mandible. A one-piece implant was placed in the 35 region. The present case used an endosteal implant, one stage surgery, and delayed loading. Restoration with porcelain fused to the metal crown had been delivered three months after the one-piece implant placement. The result of this treatment indicated that one-piece implant could be considered as an effective therapy choice for replacement of missing tooth in order to rehabilitate the masticatory function.


Subject(s)
Dental Implantation
17.
Article in English | LILACS, BBO | ID: biblio-1154999

ABSTRACT

ABSTRACT Objective: To evaluate the intra-examiner and inter-examiner reliability of linear and curvilinear measurements for the complete assessment of implant sites and jaw pathologies using Cone-Beam Computed Tomography (CBCT). Material and Methods: Fifty cone-beam computed tomographic images of patients were retrieved from the archives of Dentomaxillofacial Radiology. CBCT images taken for implant planning and evaluation of intrabony jaw pathologies (benign cyst/tumor) were included. Two expert oral and maxillofacial radiologists analyzed the images independently and made the measurements. The images for implant planning were analyzed for width, the height of the edentulous site, and the qualitative analysis of bone in the region. Jaw pathologies were assessed for linear dimensions and curvilinear measurements. Results: The inter-observer measurement error for implant site analysis ranged from 0.12 to 0.42 mm with almost perfect agreement (ICC: 0.94 to 1). The inter-observer measurement error for jaw pathology was 0.09 to 0.25 mm (ICC: 0.98-1). Curvilinear measurements showed perfect agreement between the observers. The intraobserver reliability for the various parameters used for the assessment of the implant site and jaw pathologies indicated almost perfect agreement. Conclusion: Reliability between the radiologists is high for various measurements on CBCT images taken for implant planning and jaw pathologies.


Subject(s)
Humans , Pathology, Oral , Diagnostic Imaging/instrumentation , Radiographic Image Interpretation, Computer-Assisted/instrumentation , Dental Implantation/instrumentation , Cone-Beam Computed Tomography , Mandible/diagnostic imaging , Retrospective Studies , Observational Studies as Topic/methods , Dimensional Measurement Accuracy , Radiologists , India/epidemiology , Jaw , Mandible/pathology
18.
Araçatuba; s.n; 2021. 84 p. tab, ilus, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1413753

ABSTRACT

A proposição do trabalho foi avaliar o comportamento biológico e mecânico ao tecido ósseo periimplantar em implantes manufaturados em Ti-cp com superfícies usinada (CPMS) e modificada por LASER (CPLS) e implantes manufaturados em Ti6Al4V com superfícies usinada (ALLOYMS) e modificada por LASER (ALLOYLS). As superfícies foram analisadas por meio da microscopia eletrônica de varredura acoplado a espectroscopia por energia dispersiva de raios X (MEV-EDX) previamente a cirurgia experimental. Noventa e seis (2x4mm) implantes foram instalados em leitos cirúrgicos fresados nas tíbias direita e esquerda de 48 ratos Wistar machos, sendo um implante de cada material (metal) ou superfície instalado em cada tíbia. Análise biomecânica foi realizada por meio do torque de remoção dos implantes em todos os grupos nos períodos de 14, 21 e 42 dias pós-operatório e as tíbias foram seccionadas e processadas para análise histológica e imunoistoquímica. Posteriormente, foi realizada MEV-EDX dos implantes removidos por torque reverso em todos os períodos de análises. Os dados obtidos na análise biomecânica foram submetidos à análise estatística (p< 0,05). MEV-EDX antes da instalação dos implantes apresentou diferença entre as superfícies usinadas e modificadas por LASER, independente do metal do implante. O torque de remoção de ALLOYLS foi estatisticamente superior a CPLS, CPMS e ALLOYMS em 14 e 21 dias (p < 0,05), bem como CPLS foi estatisticamente superior a CPMS e ALLOYMS. Aos 42 dias CPLS e ALLOYLS apresentaram diferenças estatística quando comparados com CPMS e ALLOYMS (p< 0,05), porém não foi observada diferença entre CPLS e ALLOYLS (p = 0,07). O MEV-EDX dos implantes removidos por contra-torque evidenciou o recobrimento ósseo total das superfícies de CPLS e ALLOYLS, independe do período analisado e um aumento gradual de recobrimento ósseo nas superfícies de CPMS e ALLOYMS nos períodos de 14, 21 e 42 dias respectivamente, sendo que o CPLS aos 42 dias apresentou característica de tecido ósseo mais maturo. Na análise histológica qualitativa observa-se um tecido ósseo mais maturo, sugerindo aceleração do processo de reparo ósseo nos grupos CPLS e ALLOYLS. Para análise imunoistoquímica observou-se uma maior expressão de OPN (osteopontina) para os grupos ALLOYLS 14 e 21 dias pós-operatório, surgindo de maior ativação celular. Os implantes com modificação de superfície por ablação a LASER, independente do material manufaturado, proporcionaram importantes modificações físico-químicas na superfície, permitindo melhor embricamento mecânico com o tecido ósseo e aceleração do processo de osseointegração quando comparados com implantes com superfície usinada(AU)


This study aimed to evaluate the biological and mechanical behavior of peri-implant bone tissue in implants manufactured in cp-Ti with machined surfaces (CPMS) and modified by LASER (CPLS) and implants manufactured in Ti6Al4V with machined surfaces (ALLOYMS) and modified by LASER (ALLOYLS). The surfaces were analyzed using scanning electron microscopy coupled with X-ray dispersive energy spectroscopy (SEM-EDX) prior to experimental surgery. Ninety-six (2x4mm) implants were installed in surgical beds milled in the right and left tibias of 48 male Wistar rats, one implant of each material (metal) or surface installed in each tibia. Biomechanical analysis was performed using the implant removal torque in all groups in the periods of 14, 21 and 42 days postoperatively and the tibias were sectioned and processed for histological and immunohistochemical analysis. The data obtained in the biomechanical analysis were submitted to statistical analysis (p < 0.05). The SEM-EDX before the installation of the implants showed a difference between the surfaces machined and modified by LASER, regardless of the metal of the implant. The removal torque of ALLOYLS was statistically higher than CPLS, CPMS and ALLOYMS in 14 and 21 days (p < 0.05), as well as CPLS was statistically higher than CPMS and ALLOYMS. In 42 days CPLS and ALLOYLS showed statistical differences when compared to CPMS and ALLOYMS (p < 0.05), however no difference was observed between CPLS and ALLOYLS (p = 0.07). The SEM-EDX of the implants removed by removal torque showed the total bone coverage of the surfaces of CPLS and ALLOYLS, regardless of the analyzed period and a gradual increase in bone coverage on the surfaces of CPMS and ALLOYMS in the periods of 14, 21 and 42 days respectively, CPLS in 42 days showed a mature bone tissue. In the qualitative histological analysis, a mature bone can be observed, suggesting an acceleration of the repair process in the CPLS and ALLOYLS groups. For immunohistochemical analysis, a higher expression of OPN (osteopontin) was observed for the ALLOYLS groups in 14 and 21 days, arising from higher cellular activation. The implants with surface modification by LASER beam, regardless of the material manufactured, provided important physical-chemical modifications on the surface, allowing better mechanical resistance with bone tissue and acceleration of the osseointegration process when compared to implants with machined surfasse(AU)


Subject(s)
Animals , Rats , Dental Implants , Osseointegration , Lasers , Bone and Bones , Microscopy, Electron, Scanning , Rats, Wistar , Dental Implantation , Dental Implantation, Endosseous
19.
Braz. dent. sci ; 24(1): 1-8, 2021. tab, ilus
Article in English | BBO, LILACS | ID: biblio-1145466

ABSTRACT

Objectives: With regard to the prevalence of abutment screw loosening (SL) and bone height reduction, particularly in the posterior regions of the jaws, as well as the contradictory issue of applying short implants instead of surgeries, along with all preparations associated with longer implants, the present study aimed to compare the amount of torque loss in short implants with increased vertical cantilever abutments and standard ones. Material and Methods: In this experimental study, a total number of 20 implants (MegaGen Implant Co., Ltd, South Korea) with 4.5 mm diameter including 10 short implants (7 mm) and 10 standard ones (10 mm) were utilized. Using a surveyor, fixtures were perpendicularly mounted in 13×34 mm resin for short implants and 19×34 mm resin for standard ones. The abutments of the same height but different cuff heights (2.5 mm for the standard implants and 5.5 mm for the short ones) were then tightened with 30 N.cm, via a digital torque meter. To compensate the settling effect, the abutment screw was re-tightened with 30 N.cm after 10 min. Upon applying 500,000 cycles at 75 N.cm and 1 Hz along the longitudinal axis on each sample, blind reverse torque value (RTV) was measured with a digital torque meter. The data were finally analyzed using Student's t-test. Results:Both groups experienced torque loss, but there was no statistically significant difference between the case and control groups in terms of abutment SL (p = 0451). Conclusion: Short implants seem to be a good mechanical alternative in emergencies with respect to torque loss and abutment SL. (AU)


Objetivos: Considerando a prevalência de afrouxamento de parafuso dos pilares, redução da altura óssea especialmente nas regiões posteriores, a questão contraditória da aplicação de implantes curtos em vez de cirurgias e todos os preparos associados a implantes mais longos, este estudo buscou comparar implantes curtos com pilares cantilever verticais aumentados e implantes padrão na quantidade de perda de torque. Material e métodos: Neste estudo experimental, foram utilizados 20 implantes (Megagen, Coreia do Sul) com diâmetro de 4,5 mm, incluindo 10 implantes curtos (7 mm) e 10 implantes padrão (10 mm). A fixação foi realizada perpendicularmente em uma resina 13 × 34 mm para implantes curtos e uma resina 19 × 34 mm para implantes padrão, usando um topógrafo. Os pilares da mesma altura, mas com diferentes comprimentos de manguito (2,5 mm para os implantes padrão e 5,5 mm para os implantes curtos) foram apertados com 30 N, utilizando um torquímetro digital. Para compensar o efeito de sedimentação, o parafuso do pilar foi reapertado com 30 N após 10 min. Depois de aplicar 500.000 ciclos a 75 N e 1 Hz ao longo do eixo longitudinal em cada amostra, o valor de torque reverso cego foi medido com um medidor de torque digital. Os dados foram analisados pelo teste t de Student. Resultados: Todos os grupos tiveram perda de torque, mas não houve diferença estatisticamente significativa entre os grupos caso e controle em termos de afrouxamento do parafuso do pilar (p = 0451). Conclusão: Os implantes curtos parecem ser uma boa alternativa mecânica em emergências em termos de perda de torque e afrouxamento do parafuso do pilar. (AU)


Subject(s)
Bone Screws , Torque , Dental Implantation
20.
Braz. dent. sci ; 24(1): 1-8, 2021. tab, ilus
Article in English | BBO, LILACS | ID: biblio-1145561

ABSTRACT

Objetivo: Avaliar a relação entre a densidade óssea medida em imagens de tomografia computadorizada (TC) e tomografia computadorizada de feixe cônico (TCFC) e relacionar com a estabilidade primária de implantes dentários. Material e métodos: Foram utilizadas neste estudo 20 cabeças femorais bovinas frescas, preparadas pela remoção de partes moles, secção do osso e colocação de marcadores para localização e angulação dos implantes. A densidade óssea da área peri-implantar foi determinada no pré-operatório em imagens TC e TCFC das amostras de osso peparado, representadas por unidades Hounsfield (HUs) e valores de cinza (GVs), respectivamente. Em seguida, 60 implantes em três tamanhos (diâmetro = 4 mm, comprimento = 8, 10 e 12 mm) foram inseridos nos ossos e o torque máximo de inserção (TI) foi registrado. O dispositivo Osstell também foi usado para determinar o quociente de estabilidade do implante (ISQ) para cada implante. A análise estatística foi realizada nos dados (α = 0,05). Resultados: Os valores médios ± DP de GV,HU e ISQ foram 1592,75 ± 231,82, 675,26 ± 115,38 e 61,90 ± 10,14, respectivamente. Além disso, o limite de TI mais frequente foi 30-35 Ncm (41,4%). Relações significativas foram observadas entre HU e IT, GV e IT, HU e ISQ, GV e ISQ, e IT e ISQ em todos os tamanhos de implante. Os GV e HU também se correlacionaram significativamente. Conclusão: Os valores da densidade óssea em imagens de TCFC e TC mostram-se positivamente associados para estabilidade primária de implantes dentários. Portanto, os GVs obtidos no Sistema de TCFC (Sirona's Galileos) poderiam ser usados para a seleção pré-operatória de sítios edêntulos que permitam uma melhor estabilidade do implante ou locais que requerem procedimentos adicionais para aumentar a taxa de sucesso dos implantes dentários. (AU)


Objective: To evaluate the relationship between bone density measured by computed tomography (CT) and cone beam computed tomography (CBCT) (Sirona's Galileos scanner) with primary stability of dental implants. Material and methods: 20 fresh bovine femoral heads were prepared by removal of soft tissue, sectioning of the bone, and placement of markers for location and angulation of implants. Bone density of peri-implant areas was determined preoperatively by CT and CBCT scanning of the prepared bone samples represented by Hounsfield units (HUs) and gray values (GVs), respectively. Then, 60 implants in three sizes (diameter = 4 mm, length = 8, 10, and 12 mm) were inserted into the bones and maximum insertion torque (IT) was recorded. Osstell device was also used for determining the implant stability quotient (ISQ) for each implant. Statistical analysis was performed on the data (α = 0.05). Results: Mean ± SD values of GV,HU, and ISQ were 1592.75 ± 231.82, 675.26 ± 115.38 and 61.90 ± 10.14, respectively. Moreover, the most frequent IT limit was 30-35 Ncm (41.4%). Significant relationships were observed between HU and IT, GV and IT, HU and ISQ, GV and ISQ, and IT and ISQ in all implant sizes. Moreover, GV and HU also significantly correlated to each other. Conclusion: Bone density values in CBCT and CT scans are positively associated to primary stability of dental implants. Therefore, GVs obtained from Galileos CBCT scanner can be used for preoperative selection of edentulous sites which allow for better implant stability or locations which require further procedures for enhancing the success rate of dental implants (AU)


Subject(s)
Animals , Cattle , Tomography, X-Ray Computed , Dental Implantation , Cone-Beam Computed Tomography
SELECTION OF CITATIONS
SEARCH DETAIL